Ht-instruments HT3310 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Narzędzia Ht-instruments HT3310. HT instruments HT3310 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
© Copyright HT ITALIA 2012 Release EN 1.03 - 13/01/2012
ENGLISH
User manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - User manual

© Copyright HT ITALIA 2012 Release EN 1.03 - 13/01/2012 ENGLISH User manual

Strona 2

HT3301-HT3310 EN - 9Emissivity of common metal, refractory and buildings materials is shown in Table 2 Object Emissivity Object Emissivity Zin

Strona 3

HT3301-HT3310 EN - 106. OPERATING INSTRUCTIONS 6.1. TEMPERATURE MEASUREMENT 6.1.1. Infrared measurement mode 1. Select the desired additional

Strona 4 - 2. GENERAL DESCRIPTION

HT3301-HT3310 EN - 116.1.2. Type K measurement mode (HT3301 only) 1. Pressing the MODE button, select the “TK” symbol according to paragraph 4

Strona 5 - 3. PREPARATION TO USE

HT3301-HT3310 EN - 128. MAINTENANCE 8.1. GENERAL 1. This meter is a precision instrument. Whether in use or in storage, please do not exceed th

Strona 6 - 4. INSTRUMENT DESCRIPTION

HT3301-HT3310 EN - 139. TECHNICAL SPECIFICATIONS Accuracy is indicated as [% of reading + degree]. It is referred to the following reference con

Strona 7

HT3301-HT3310 EN - 149.2. ENVIRONMENTAL CONDITIONS 9.2.1. Climatic condition Operating temperature: 0°C ÷ 50°C (32°F ÷122°F) Operating humidit

Strona 8

HT3301-HT3310 EN - 1510. SERVICE 10.1. WARRANTY CONDITIONS This instrument is guaranteed against material or production defects, in accordance w

Strona 9 - 5. PARAMETERS SETTINGS

HT3301-HT3310 EN - 1Table of Contents: 1. SAFETY PRECAUTIONS AND PROCEDURES ... 2 1.1.

Strona 10

HT3301-HT3310 EN - 21. SAFETY PRECAUTIONS AND PROCEDURES This instrument complies with EMC standards related to electronic measuring equipment

Strona 11 - 6. OPERATING INSTRUCTIONS

HT3301-HT3310 EN - 31.2. DURING USE Read carefully the following recommendations and instructions: CAUTION • Be careful not activate the tri

Strona 12 - 7. MEMORY (HT3301 only)

HT3301-HT3310 EN - 43. PREPARATION TO USE 3.1. INITIAL CONTROL This instrument was checked both mechanically and electrically prior to shipment

Strona 13 - CAUTION

HT3301-HT3310 EN - 54. INSTRUMENT DESCRIPTION 4.1. FRONTAL PANEL LEGEND: 1. IR sensor 2. Laser pointer beam 3. LCD Display 4. down button 5

Strona 14 - 9. TECHNICAL SPECIFICATIONS

HT3301-HT3310 EN - 64.4. DESCRIPTION OF FUNCTION KEYS LEGEND: 1. Up button 2. MODE button (for cycling through the mode loop) 3. Down button 4

Strona 15

HT3301-HT3310 EN - 74.4.2. Switch °C / °F, LOCK ON/OFF and SET ALARM LEGEND: 1. C/F 2. LOCK ON/OFF 3. SET ALARM Fig. 4: Description of inter

Strona 16 - 10. SERVICE

HT3301-HT3310 EN - 85. PARAMETERS SETTINGS 5.1. EMISSIVITY ADJUSTMENT 5.1.1. Definition Emissivity is a term used to describe the energy-emittin