HT6-HT8-HT9
EN - 6
4.2. AUTO POWER ON MODE / SWITCHING ON
The instruments switch on in the following cases:
if continuity is detected;
if an AC or DC voltage higher than 10V is detected;
if a live phase is connected to lead L2;
of the Torch button is pressed;
if the ON/Reset button is pressed (on models HT6 and HT8);
if the Lamp test button is pressed (on model HT9)
4.3. AUTO POWER OFF MODE
The following conditions are possible:
the instruments automatically switch off if no signal is detected in contact with leads
for 5 seconds;
the torch light turns off after 10 seconds after the torch button has been released;
the lamp test is stopped and the instrument switches off after 5 seconds when the
Lamp test button is released.