HT9012
EN - 15
6.1.1 Safety
Comply with: IEC/EN 61010-1
Insulation: double insulation
Pollution degree: 2
For inside use, max height: 2000m (6562 ft)
Installation category: CAT IV 600V, CAT III 1000V to ground
6.1.2 General data
Mechanical characteristics
Dimensions (L x W x H): 215 x 74 x 43mm ; 8 x 3 x 2 in
Weight (including battery): 285g (10 ounces)
Max conductor size: 30mm (1in)
Supply
Battery type: 1x9V alkaline battery NEDA 1604 IEC 6F22
Low battery indication:
” is displayed when the battery level is too low
AutoPowerOFF after 15min of idleness (not disabled)
Display
Characteristics: 3½ LCD (max 2000 points) plus decimal point, unit
symbol indication and backlight
Sample rate: 2 times/sec
Conversion mode: Mean value
6.2 ENVIRONMENTAL CONDITIONS
6.2.1 Climatic conditions
Reference temperature: 23° ± 5°C (73°F ± 41°F)
Operating temperature: 5 ÷ 40°C (41°F ÷ 104°F)
Operating humidity: <80%RH
Storage temperature: -20 ÷ 60 °C (-4°F ÷ 140°F)
Storage humidity: <80%RH
This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC and to EMC directive 2004/108/EEC
6.3 ACCESSORIES
6.3.1 Standard accessories
The content of a standard package is the following:
Instrument HT9012
Test leads - Cod. 4413-2
Carrying bag
Battery
User manual